N. Hydraulic openings/flood vents. New                                      electrical and other non-
   construction or substantial improvement of                               automatic mechanical means.
   any structure in Zones A, AE, AO, and AH that             3.   The enclosed area shall not be used for
   meets the development standards of                             human habitation.
   Subsection 12.4.5, including the elevation                4.   The enclosed areas are usable solely for
   requirements of Subsection 12.4.5(H), (I), or (J)              building access, parking vehicles, or storing
   and is elevated on posts, columns, piers, piles,               of articles and equipment used for
   or crawl spaces may be enclosed below the                    maintenance of the building.
   base flood elevation requirements provided all        O. Bridges. New construction or substantial
   the following criteria are met or exceeded:               improvement of any bridge in Zones A, AE, AO,
   1.   Enclosed areas are not basements as                  AH, and VE shall be designed such that:
        defined in Article 3.                                1.   When possible, the lowest horizontal
   2.   Enclosed areas shall be designed to                       member (excluding the pilings, or
        automatically equalize hydrostatic flood                  columns) is elevated to at least two feet
        forces on exterior walls by allowing for the              above the base flood elevation.
        entry and exit of flood water. Designs for           2.   A registered professional engineer shall
        meeting this requirement must either:                     certify that:
        a.   Be engineered and certified by a                     a.   The structural design and methods of
             registered professional engineer or                       construction shall meet the elevation
             architect, or                                             requirements of this section and the
        b.   Meet or exceed the following                              floodway standards of Subsection
             minimum criteria:                                         12.4.5(M).
             i.    A minimum of two openings                      b.   The foundation and superstructure
                   having a total net area of not less                 attached thereto is anchored to resist
                   than one square inch for every                      flotation, collapse, and lateral
                   square foot of the enclosed area;                   movement due to the effects of wind
             ii.   The bottom of all openings shall                    and water loads acting simultaneously
                   be below the base flood elevation                   on all structural components. Water
                   and no higher than two feet                         loading values used shall be those
                   above the lowest grade.                         associated with the base flood.
             iii. Openings may be equipped with          P. Containment walls. New construction or
                   screens, louvers, valves, or other        substantial improvement of any containment
                   coverings or devices provided             wall shall meet the following requirements by
                   that they permit the entry and            zone:
                   exit of flood waters automatically        1.   Zones A, AE, AO, AH, and VE shall:
                   without any external influence or              a.   Have the containment wall elevated
                   control such as human                               to at least two feet above the base
                   intervention, including the use of                  flood elevation; CITY OF PORTLAND LAND USE CODE | 12-13 FLOODPLAIN MANAGEMENT