INTERNAL PROTOTYPE — NOT LEGAL ADVICE — DO NOT SEND

Portland Land Use Code

Citation
Portland Land Use Code
Parent Document
Portland Land Use Code
Jurisdiction
Portland (municipal)

Other Sections in This Document (765)

Full Text

3,819 chars
b.   Be limited in size to a one-story two-           within the city during the occurrence of
               car garage.                                      the base flood discharge.
          c.   Have unfinished interiors and not be        2.   In Zones A and AE riverine areas for which
               used for human habitation.                       no regulatory floodway is designated,
          d.   Have hydraulic openings, as specified            encroachments, including fill, new
               in Subsection 12.4.5(N)(2), in at least          construction, substantial improvement,
               two different walls of the accessory             and other development shall not be
               structure.                                       permitted in the floodway as determined
          e.   Be located outside the floodway.                 in (3) below, unless a technical evaluation
          f.   When possible be constructed and                 certified by a registered professional
               placed on the building site so as to             engineer is provided demonstrating that
               offer the minimum resistance to the              the cumulative effect of the proposed
               flow of flood waters and be placed               development, when combined with all
               further from the source of flooding              other existing development and
               than is the primary structure.                   anticipated development:
          g.   Have only ground fault interrupt                 a.   Will not increase the water surface
               electrical outlets. The electric service              elevation of the base flood more than
               disconnect shall be located above the                 one foot at any point within the city.
               base flood elevation and when                    b.   Is consistent with the technical criteria
               possible outside the special flood                    contained in FEMA’s guidelines and
               hazard area.                                          standards for flood risk analysis and
          h.   Be located outside the Coastal AE                     mapping.
               Zone.                                       3.   In Zones A and AE riverine areas for which
    2.   Accessory structures in Zones VE and                   no regulatory floodway is designated, the
         Coastal A shall meet the requirements of               regulatory floodway is determined to be
       Subsection 12.4.5(R).                                    the channel of the river or other
M. Floodways                                                    watercourse and the adjacent land areas to
    1.   In Zone AE riverine areas, encroachments,              a distance of 1/2 the width of the floodplain
         including fill, new construction, substantial          as measured from the normal high-water
         improvement, and other development shall               mark to the upland limit of the floodplain.
         not be permitted within a regulatory                   Encroachments, including fill, new
         floodway designated on the Flood                       construction, substantial improvement,
         Insurance Rate Map unless a technical                  and other development shall not be
         evaluation certified by a registered                   permitted unless a technical evaluation
         professional engineer is provided                      certified by a registered professional
         demonstrating that such encroachments                  engineer is provided meeting the
         will not result in any increase in flood levels        requirements of (2) above. 12-12 | CITY OF PORTLAND LAND USE CODE FLOODPLAIN MANAGEMENT