INTERNAL PROTOTYPE — NOT LEGAL ADVICE — DO NOT SEND

Portland Land Use Code

Citation
Portland Land Use Code
Parent Document
Portland Land Use Code
Jurisdiction
Portland (municipal)

Other Sections in This Document (765)

Full Text

3,733 chars
perimeter. Parking structures and the            C. Minimum setback exceptions for
         buildings for public transportation facilities       nonconforming lots
         may, however, be set back beyond the key             1.   In the case of a nonconforming lot existing
         building envelopes (toward the interior of                as of June 5, 1957 in the RN-1, RN-2, RN-3,
         blocks), but may not occupy the land                      and RN-4 zones and less than 100 feet
         between the key building envelope and the                 deep, the front setback need not be
         street right-of-way.                                      deeper than 20% of the depth of the lot.
    8.   Build-to zone requirements shall not apply           2.   In the case of a nonconforming lot existing
         to additions to existing buildings as follows:            as of June 5, 1957 in a residential zone, the
         a. Build-to zone requirements shall not                   required side setback for principal
              apply to vertical additions to existing              structures may be reduced in order to
              buildings to meet minimum height                     provide a buildable width of up to 24 feet
              requirements.                                        as follows:
         b.   In the B-1, B-2, and B-2b zones, build-to            a. RN-1, RN-2: No side setback shall be
              zone requirements shall not apply to                        reduced to less than 5 feet.
              additions to buildings existing as of                b.     RN-3: One side setback may be
              the effective date of this Code that do                     reduced to zero feet, provided the
              not cumulatively exceed 50% of the                          other shall be reduced to not less than
              building footprint as the effective date                    5 feet. A permanent maintenance
              of this Code. However, any such                             easement a minimum of 5 feet in
              additions shall increase conformity                         width shall be provided on the parcel
              with the standards to the extent                            adjacent to the lot line with the zero
              practicable.                                                foot setback.
         c.   In the B-4, B-5, B-6, TOD-1, and TOD-2
              zones, build to zone requirements           7.6.6 Stepbacks and areas of limited height
              shall not apply to additions to                 adjacent to RN or open space zones
              buildings existing as of the effective      A. A cornice eave, sill, canopy, chimney, bay
              date of this Code that do not                   window, balcony, or other similar architectural
              cumulatively exceed 25% of the                  feature may project into any required stepback
              building footprint as of the effective          or area of limited height adjacent to an RN or
              date of this Code. However, any such            open space zone a distance of not more than
              additions shall increase conformity             two feet.
              with the standards to the extent            B. Building mounted mechanical equipment may
              practicable.                                    encroach into a required stepback or area of
                                                              limited height adjacent to an RN or open space
                                                              zone by no more than 50% of the width of such 7-26 | CITY OF PORTLAND LAND USE CODE DIMENSIONAL STANDARDS