INTERNAL PROTOTYPE — NOT LEGAL ADVICE — DO NOT SEND

Portland Land Use Code

Citation
Portland Land Use Code 1.
Parent Document
Portland Land Use Code
Jurisdiction
Portland (municipal)

Other Sections in This Document (765)

Full Text

2,165 chars
1.   Critical uses. The SLR-DFE for all critical              supporting the second floor in a multi-
        uses (SLR-DFE-C), including the critical                 story building, or the roof in a one-story
        systems serving such uses, shall be a                    building, shall be no less than 13 feet above
        minimum of one foot above SLR-BFE, as                    SLR-BFE. In a proposed project containing
        defined in Article 3. In a proposed project              non-critical uses, the following building and
        containing critical uses, the following                  site elements are permitted to be located
        building and site elements are permitted to              below SLR-DFE:
        be located below the SLR-DFE:                            a.   Lobbies, entries, egress stairs, and
        a.   Lobbies, entries, egress stairs, and                     elements required for vertical
             elements required for vertical                           circulation from the SLR-DFE to grade,
             circulation from the SLR-DFE to grade,                   such as elevators, ramps, and stairs.
             such as elevators, ramps, and stairs.               b.   Parking.
        b.   Parking.                                            c.   Storage.
        c.   Storage.                                            d.   Flood protection equipment.
        d.   Flood protection equipment.                    3.   Exempt uses. Exempt uses shall not be
   2.   Non-critical uses. The SLR-DFE for non-                  subject to dimensional requirements with
        critical uses (SLR-DFE-NC), including the              respect to SLR-BFE.
        critical systems serving those uses, shall be   B. Building height. Within the CFROZ, if a
        no lower than two feet below SLR-BFE, as            proposed project contains principal critical or
        defined in Article 3. The minimum                   non-critical uses on the ground floor, height
        elevation of the underside of the beams             shall be measured from the SLR-DFE or from CITY OF PORTLAND LAND USE CODE | 8-5 OVERLAY ZONES