constructed and maintained in such a manner             elevation, or together with attendant utility
     that no reduction occurs in the flood carrying          and sanitary facilities shall:
     capacity of the watercourse.                            a.   Be floodproofed to at least two feet
F.   Residential. New construction or substantial                 above the base flood elevation so that
     improvement of any residential structure                     below that elevation the structure is
     located within:                                              watertight with walls substantially
     1.   Zones A1-30, AE, and AH shall have the                  impermeable to the passage of water.
          lowest floor (including basement) elevated         b.   Have structural components capable
          to at least two feet above the base flood               of resisting hydrostatic and
          elevation.                                              hydrodynamic loads and the effects of
     2.   Zones AO and AH shall have adequate                     buoyancy.
          drainage paths around structures on                c.   Be certified by a registered
          slopes, to guide flood water away from the              professional engineer or architect that
          proposed structures.                                    the design and methods of
     3.   Zone AO shall have the lowest floor                     construction are in accordance with
          (including basement) elevated above the                 accepted standards of practice for
          highest adjacent grade:                                 meeting the provisions of this section.
          a.   At least two feet higher than the                  Such certification shall be provided
               depth specified in feet on the                     with the application for a Flood
               community’s Flood Insurance Rate                   Hazard Development Permit, as
               Map, or                                            required by Subsection 12.4.2(G) and
          b.   At least three feet if no depth number             shall include a record of the elevation
               is specified.                                      above mean sea level to which the
     4.   Zone A shall have the lowest floor                      structure is floodproofed.
          (including basement) elevated to at least     2.   Zones AO and AH shall have adequate drainage paths
          two feet above the base flood elevation            around structures on slopes, to guide flood water
          utilizing information obtained pursuant to         away from the proposed structures.
          Subsections 12.4.2(D)(2), 12.4.4(B)(4), or    3.   Zone AO shall have the lowest floor
          12.4.4(C)(1).                                      (including basement) elevated above the
     5.   Zones V1-30 and VE shall meet the                  highest adjacent grade:
          requirements of Subsection 12.4.5(P).              a.   At least two feet higher than the
G. Nonresidential. New construction or                            depth specified in feet on the
     substantial improvement of any nonresidential                community’s flood insurance rate
     structure located within:                                    map, or
     1.   Zones A1-30, AE, and AH shall have the             b.   At least three feet if no depth number
          lowest floor (including basement) elevated              is specified, or
          to at least two feet above the base flood          c.   Together with attendant utility and
                                                                  sanitary facilities be floodproofed to 12-6 | CITY OF PORTLAND LAND USE CODE FLOOD PLAIN MANAGEMENT