shall be less than the minimum required for a       F.   Maximum front setbacks
     one-story building.                                      1.   Maximum front setbacks shall not apply to
B.   Setbacks in the O-P zone. The Planning Board                  utility substations and secondary building
     may reduce by up to 50% the minimum setback                   components.
     if another yard within the lot is correspondingly        2.   In the B-1/B-1b zone. Building additions are
     increased so that the combined minimum yards                  encouraged but not required to meet
     on all four sides equal 150 feet. If two or more              front setbacks.
     buildings are located on one lot, only the               3.   In the B-2/B-2b/B-2c zones
     requirements of the front, rear or side setbacks              a.   Building additions do not have to
     that adjoin any external property boundary                         meet maximum front setback
     must be met, provided a sufficient fire line is                    requirements.
     provided.                                                     b.   The Planning Board or Planning
C.   Projections in required setback areas. Any                         Authority may approve a different
     setback may be occupied by a one-story                             front setback for irregularly shaped
     entrance porch not enclosed, with or without a                     lots or lots with frontage greater than
     roof, if the area of the porch does not exceed                     40 feet in width provided the front
     50 square feet nor the projection from the                         setback is met to the maximum extent
     building exceed six feet. A basement bulkhead                      practicable.
     of similar size, but not more than 24 inches in               c.   If a lot has less than 40 feet of
     height, is also permitted. A cornice eave, sill,                   frontage and is more than 100 feet
     canopy, chimney, bay window, balcony, or                           deep, then no maximum setback is
     other similar architectural feature may project                    required.
     into any required setback a distance of not                   d.   If existing structures are within 20 feet
     more than two feet.                                                of the street or meet the front
D. Pavement setbacks. Pavement setbacks shall                           setback maximum and the remainder
     not apply to entrance drives.                                      of the lot has less than 40 feet of
E.   Corner lot setbacks. In case a principal                           frontage, then no maximum setback is
     residential structure has its front yard upon the                  required.
     long side of a corner lot, the rear setback may               e.   The Planning Board or Planning
     be reduced to a depth not less than the                            Authority may waive the maximum
     required side setback on the lot, provided that                    front setback for utility substations
     the aggregate of the widths of both sides and                      and alternative energy installations.
     depths of front and rear yards is not less than               f.   Where setbacks exceed 10 feet, a
     the similar aggregate of required dimensions of                    continuous, attractive, and pedestrian-
     all setbacks if the front yard were faced on the                   scaled edge treatment shall be
     short side of the lot.                                             constructed along the street,
                                                                        consisting of street trees spaced at no CITY OF PORTLAND LAND USE CODE | 7-21 DIMENSIONAL STANDARDS