F.   Where any part of the proposed solar energy          B.   Wind energy systems and associated facilities,
     system (including associated facilities) is within        including foundations and support structures,
     a historic district, such development shall be            electrical connections and control equipment,
     reviewed and approved by the Planning                     associated site improvements, and
     Authority in accordance with Article 17. Where            construction techniques, shall be designed,
     any part of the proposed solar energy system              engineered, and installed to comply with all
     (including support structures and associated              applicable local, state, and federal construction
     facilities) is within 100 feet of any designated          and electrical regulations and Federal Aviation
     landmark, historic district, or historic landscape        Administration regulations. Applicable state and
     district, such development shall meet the                 local approvals shall be obtained prior to
     standards of Article 14 regarding compatibility           installation of any wind energy system.
     with the landmark or historic district.              C.   The support structure (e.g. tower, pole) for
G. Solar energy systems shall minimize impacts                 freestanding wind generating systems shall not
     resulting from construction and maintenance               be climbable for a minimum height of 12 feet
     of the solar energy system, including lighting,           above the surrounding ground level or
     security measures, traffic, and grid connections.         accessible surface. All ground-mounted
H. Where permitted in residential zones, and in                electrical and control equipment shall be
     the B-1/B-1b, B-2/B-2b/B-2c, B-3/B-3b/B-3c, B-7           labeled and secured to prevent unauthorized
     and waterfront zones, all solar energy systems            access.
     shall be co-located with other land uses.            D. All moving components of a wind energy
I.   Major solar energy systems shall be located on            system shall be a minimum of 12 feet from
     areas already paved or built upon, or where               ground level or accessible surface.
     other development is documented to be                E.   All on-site electrical wiring associated with the
     unlikely due to local conditions.                         proposed wind energy system shall be located
                                                               within the tower/pole/supporting structure and
6.4.17 Tow lots                                                underground. Above ground on-site
Tow lots must be at least 300 feet from any                    connections near substations or to the electric
residential zone or conforming residential use.                grid shall be allowed.
                                                          F.   The use of guy wires is discouraged. If
6.4.18 Wind energy systems                                     required, they shall be located away from
A.   All wind energy generation equipment shall be             pedestrian routes/access points and marked
     approved under a certification program                    with visible, reflective, colored objects, such as
     approved by the U.S. Department of Energy                 flags, reflectors, or tape, which shall be placed
     such as the Underwriters Laboratories,                    on the anchor points of guy wires and along the
     Germanishcer Lloyd Wind Energies, or other                guy wires up to a height of ten feet from the
     similar certifying organizations. Experimental,           ground.
     homebuilt, and prototype models shall not be         G. No wind energy system shall be located within
     permitted.                                                250 feet of any significant wildlife habitat, as 6-18 | CITY OF PORTLAND LAND USE CODE USE STANDARDS