Skip to main content

77 Ill. Adm. Code Part 860

Citation
77 Ill. Adm. Code Part 860
Jurisdiction
Illinois (state)
Source
Official source

Full Text

1,048 chars
Section 860.ILLUSTRATION F Manufactured Home Community Electrical System
DPH 77 ILLINOIS ADMINISTRATIVE CODE 860 860.Tab.a

Section 860.TABLE A Minimum Road Width

Minimum Road Width
(In feet)

Way Traffic Two Way Traffic

No Parking on Streets 18 24

Parking on Streets 24 30

Parking on Both Sides 30 36
DPH 77 ILLINOIS ADMINISTRATIVE CODE 860 860.Tab.b

Section 860.TABLE B Water Distribution Pipe Size

Number of
Inside Diameter of Manufactured Home Maximum Length
Main (In inches) Sites Connected of Main (In feet)

2 20 600
3 60 1,800
4 120 3,600
6 400 12,000

NOTE: If local requirements exceed the above sizes, the local standards must be met. A
minimum 6-inch diameter pipe is required if fire hydrants are installed in the water
distribution system. (See Section 860.270(d).)

(Source: Amended at 30 Ill. Reg. 13419, effective July 28, 2006)
DPH 77 ILLINOIS ADMINISTRATIVE CODE 860 860.Tab.c

Section 860.TABLE C Minimum Size and Slope of Sewer Mains

Inside

Number of Sites (Inches) Minimum Slope

1-125 6 0.75%
more than 125 8 0.40%