with fire hydrants within 500 feet of any structure in the manufactured home
community. As an alternative to fire hydrants, a holding pond or other source of
water of 100,000 gallons or more accessible to the fire department or fire
protection district may be used, if the fire department or fire protection district is
capable of pumping from the body of water. The minimum size water main for
providing fire protection shall be six inches in diameter. The system shall be
designed to maintain a minimum pressure of 20 psi at all points in the distribution
system under normal conditions of flow. (See Table B.) (Type A Violation)
e) Flammable liquids and gasoline-powered equipment other than motorized
vehicles shall not be stored within five feet of a manufactured home, except when
stored in a shed or garage. (Type B Violation)
f) All intended means of egress shall not be obstructed. (Type C Violation)
(Source: Amended at 43 Ill. Reg. 2558, effective February 6, 2019)
Section 860.280 Lighting
Communities constructed after July 1, 1998 shall have an average illumination level of at least
0.6 foot candles and a minimum illumination level of 0.3 foot candles maintained for all streets
in the manufactured home community. (Type A Violation)
(Source: Amended at 43 Ill. Reg. 2558, effective February 6, 2019)
Section 860.290 Pools and Beaches
Swimming pools and bathing beaches, if provided, shall be constructed and operated in
accordance with the Swimming Facility Code. Separate construction permits and licenses are
required in accordance with the Swimming Facility Act. (Type A Violation)
(Source: Amended at 43 Ill. Reg. 2558, effective February 6, 2019)
Section 860.300 Solid and Landscape Waste