77 Ill. Adm. Code Part 860

Citation
77 Ill. Adm. Code Part 860
Jurisdiction
Illinois (state)
Source
Official source

Full Text

1,622 chars
2) For homes installed after July 1, 1998, the manufactured home community
licensee shall be responsible for providing electrical service equipment at
least equivalent to the amperage capacity of the home which it serves.
(Type A Violation)

b) Existing Installations
The following minimum requirements shall apply to electrical systems installed
prior to July 1, 1998:

1) The electrical distribution system to the manufactured home sites shall be
single phase, 120/240 volts nominal. (Type A Violation)

2) The type, size, installation and location of all conductors shall comply
with their approved use as indicated in the edition of the National
Electrical Code in effect at the time of construction. (Type A Violation)

3) The service equipment shall not be attached to the home, located under the
home, or located anywhere that is not readily accessible. Obstructions
such as bushes shall not be located within three feet of the front of the
service equipment. (Type A Violation)

4) All electrical equipment installed outdoors shall be the weatherproof type.
Equipment located under the home shall be protected from the weather.
(Type C Violation)

5) The service equipment and any other electrical devices shall be at least 12
inches above grade and secured to prevent any movement. (Type B
Violation)
DPH 77 ILLINOIS ADMINISTRATIVE CODE 860 860.250

6) The manufactured home feeder conductor shall be either a cord which
meets the requirements of the manufacturer of the home or a permanently
installed feeder as specified by the National Electrical Code in effect at the
time of installation. (Type C Violation)