Full Text

571 chars
Improper fastening of the chimneys was observed either by the Trustees’ expert or others at Units 5, 6, 9, 11, 12, 19, 22, 26, 27, 30, 59, 64, 68, 70, 71, 78, 85, 86 and 87, for a total of 19 units. The reasonable and necessary repair to these chimneys is to install steel angles or a carriage bolt directly from the base of the chimney enclosure to the rafters. In addition, it would be necessary to install headers in each of the chimneys, and in some instances it would become necessary to install headers in the process of fastening external portions of the chimneys.