The attic ceilings, upon examination, were without vapor barriers and vented areas of at least one square foot must be provided for each 1.50 square feet of ceiling area. The ridge vent must be at least three feet above the level of the eave vent. As for the A units, the square footage of relevant ceiling areas is approximately 350 square feet, and there is no proper ventilation installed in said units. In the B-2 units, the square footage of the ceiling area is approximately 288 square feet and in Unit 80, no venting was installed. In the C units, the square footage is 275 to 340 square feet for the C-l and C-2 units respectively. In the C units, insulation was stuck between the rafters and no ridge vents were provided; in effect, there was no ventilation.