Maintain heat in all habitable rooms, baths, and toilet rooms at an inside temperature,
as measured at a point 3 feet above the floor and 2 feet from exterior walls, of at
least 68 degrees Fahrenheit between the hours of 7 a.m. and 10:30 p.m. and 58 degrees
Fahrenheit between the hours of 10:30 p.m. and 7 a.m. from September 1 until June
30, unless the tenant is contractually obligated to provide heat;
4.
Install smoke detectors on the ceiling or on the wall not less than 4 inches nor more
than 12 inches from the ceiling at a point or points centrally located in a corridor,
inside each sleeping room, and immediately outside each sleeping room, and test smoke
detectors when each housing unit becomes vacant;
5.
Install carbon monoxide alarms outside each sleeping room and on each level of the
dwelling unit, and inside any sleeping room that contains a fuel-burning appliance
or fireplace, and test carbon monoxide alarms when each housing unit becomes vacant;
6.
Make all needed repairs or replace smoke detectors and carbon monoxide alarms with
operating devices before a unit is reoccupied; and
7.
Instruct tenants as to the purpose, operation, and maintenance of the detectors and
alarms and have the tenant sign a statement of understanding.