Skip to main content
DRAFT FOR ATTORNEY REVIEW — NOT FINAL

§ 27-2072

Citation
§ 27-2072
Parent Document
N.Y.C. Admin. Code Title 27, ch. 2 (Article 4: Minimum Room Sizes and Occupancy Regulations)
Jurisdiction
NYC (municipal)

Full Text

1,309 chars
§ 27-2072 Fire protection.
   a.   In a multiple dwelling, the owner shall fire-retard in every kitchen and kitchenette all combustible material immediately underneath or within one foot of any apparatus used for cooking or warming food; or shall cover such combustible material with asbestos of at least three-sixteenths of an inch in thickness and twenty-six gauge metal, or with fire resistive material of equivalent rating, except where such cooking or warming apparatus is installed in accordance with requirements established by the department in conformity with generally accepted safety standards. There shall be at least two feet of clear space above the exposed cooking surface of any such apparatus.
   b.   In a multiple dwelling, the owner shall, in every kitchenette, either fire-retard the ceilings and walls, exclusive of doors, or install one or more sprinkler heads to fuse at a temperature not higher than two hundred and twelve degrees Fahrenheit. Such heads shall be connected to the water supply through a pipe of at least one-half inch in diameter. Any kitchenette which was accepted or approved by the department on or before July first, nineteen hundred fifty-two and maintained in accordance with such acceptance or approval shall be deemed to be in compliance with this subdivision.